Long WPL45-12N
Long WPL45-12N
![](https://msk.wybor-battery.com/sites/default/files/styles/300x300/public/images/wpl45-12n.png?itok=YgYgjMwx)
Specification
Rated voltage (В)
12 V
Nominal capacity
20 hours (2.25 А to 10.50 V) 45 Ah, 10 hours (4.275 А to 10.50 V) 42.75 Ah, 5 hours (7.65 А to 10.20 V) 38.25 Ah, 1 C (45 А to 9.60 V) 28.5 Ah, 3 C (135 А to 9.60 V) 18 Ah
Weight
Aprox. 14.6 kg
Internal resistance (при 1 кГц)
Aprox. 7.5 mOhm
Maximum discharge current для
5 secунд: 540 А
Charging methods at 25 °С (77 °F)
Maximum charging current: 13.5 А, Use in standby mode:, Floating charging voltage from 13.5 to 13.8 V, Coefficient -3.0 мВ/˚С/Эл.
Operating temperature range
Charge from -15 °С (5 °F) to 40 °С (104 °F), Discharge from -15 °С (5 °F) to 50 °С (122 °F), Storage from -15 °С (5 °F) to 40 °С (104 °F)
Charge conservation (shelf life) at 20 °С (68 °F)
1 month 92%, 3 monthа 90%, 6 months 80%
Housing material
ABS UL94 HB, Option: Flame resistance (UL94 V-0)
Расчетный срок службы и стандарт
Ожидаемый расчетный срок службы: 6-9 years at 20 °С по данным Eurobat
Terminal
F8
*The battery must be charged before use. At higher ambient temperatures, storage time is reduced
Dimensions
Length
199
Width
166
Height
171
Height (full)
171
![](https://msk.wybor-battery.com/sites/default/files/blueprints/long_wpl45-12n.png)
Discharge rate in watts to various final voltages at 25 °С
Vремя/Конеhное напряжение | 1.85 V | 1.80 V | 1.75 V | 1.70 V | 1.67 V | 1.65 V | 1.60 V |
5 min | 233 | 280 | 314 | 336 | 341 | 347 | 354 |
10 min | 148 | 178 | 200 | 214 | 217 | 221 | 225 |
15 min | 116 | 136 | 150 | 159 | 162 | 164 | 167 |
30 min | 62.0 | 73.0 | 80.5 | 85.4 | 86.5 | 88.1 | 89.4 |
60 min | 48.8 | 51.8 | 53.6 | 54.9 | 55.3 | 55.9 | 56.4 |
120 min | 25.7 | 27.3 | 28.2 | 28.9 | 29.2 | 29.5 | 29.7 |
180 min | 20.5 | 21.8 | 22.5 | 23.1 | 23.2 | 23.5 | 23.7 |
240 min | 16.4 | 17.4 | 18.0 | 18.4 | 18.7 | 18.8 | 19.0 |
300 min | 14.0 | 14.9 | 15.4 | 15.7 | 15.9 | 16.0 | 16.2 |
600 min | 8.23 | 8.74 | 9.04 | 9.26 | 9.35 | 9.44 | 9.52 |
1200 min | 4.34 | 4.61 | 4.76 | 4.88 | 4.93 | 4.98 | 5.02 |
Discharge rate in amperes to various final voltages at 25 °С
Vремя/Конеhное напряжение | 1.85 V | 1.80 V | 1.75 V | 1.70 V | 1.67 V | 1.65 V | 1.60 V |
5 min | 127 | 153 | 171 | 183 | 186 | 190 | 193 |
10 min | 79.5 | 95.6 | 107 | 114 | 116 | 118 | 121 |
15 min | 60.3 | 71.0 | 78.3 | 83.1 | 84.2 | 85.6 | 87.0 |
30 min | 31.7 | 37.3 | 41.1 | 43.6 | 44.2 | 45.0 | 45.7 |
60 min | 24.6 | 26.1 | 27.0 | 27.7 | 27.9 | 28.2 | 28.4 |
120 min | 12.9 | 13.7 | 14.2 | 14.6 | 14.7 | 14.8 | 14.9 |
180 min | 10.3 | 10.9 | 11.3 | 11.5 | 11.6 | 11.8 | 11.9 |
240 min | 8.20 | 8.70 | 9.00 | 9.22 | 9.31 | 9.40 | 9.48 |
300 min | 6.97 | 7.40 | 7.65 | 7.84 | 7.91 | 7.99 | 8.06 |
600 min | 4.10 | 4.35 | 4.50 | 4.61 | 4.65 | 4.70 | 4.74 |
1200 min | 2.15 | 2.28 | 2.36 | 2.42 | 2.44 | 2.47 | 2.49 |